CE Series
CE Series
Brackish Water RO Elements (Cellulose Acetate)
GE Power Water & Process Technologies
The C-Series family, a triacetate/diacetate blend, has a higher flux and better mechanical stability than standard cellulose acetate. CA-Series elements offer an increased chlorine resistance compared to thin-film elements. CE Brackish Water Elements are used for brackish water desalination and process stream concentration.
Table 1: Element Specification
Membrane C-Series, Cellulose Acetate
Model | Average permeate flow gpd (m3/day)1,2 | Average NaCl rejection1,2 | Minimum NaCl rejection1,2 |
---|---|---|---|
CE4026F | 1,300 (4.9) | 97.5% | 95.0% |
CE4040FM | 1,900 (7.1) | 97.5% | 95.0% |
CE8040F | 6,400 (24.2) | 97.5% | 95.0% |
CE8040F,WET | 6,400 (24.2) | 97.5% | 95.0% |
1Average salt rejection after 24 hours operation. Individual flow rate may vary +25%/-15%.
2Testing conditions: 2,000ppm NaCl solution at 425psi (2,930kPa) operating pressure, 77°F (25°C), pH 6.5 and 15% recovery.
Model | Active area ft2 (m2) | Outer wrap | Part Number |
---|---|---|---|
CE4026F | 59 (5.5) | Fiberglass | 1206875 |
CE4040FM | 95 (8.4) | Fiberglass | 3050079 |
CE8040F | 350 (32.5) | Fiberglass | 1206880 |
CE8040F,WET | 350 (32.5) | Fiberglass | 3097264 |
Figure 1a: Element Dimensions Diagram – Male
Figure 1b: Element Dimensions Diagram – Female
Table 2: Dimensions and Weight
A, B2, C3 Dimensions, Inches (cm)
Model1 | A | B2 | C3 | Boxed Weight lbs (kg) |
---|---|---|---|---|
CE4026F | 26.0 (66.7) | 0.625 (1.59) | 3.9 (9.9) | 6 (2.7) |
CE4040FM | 40.0 (101.6) | 0.75 (1.90) OD | 3.9 (9.9) | 8 (3.5) |
CE8040F | 40.0 (101.6) | 1.125 (2.86) | 7.9 (20.1) | 32 (14.5) |
CE8040F,WET | 40.0 (101.6 | 1.125 (2.86) | 7.9 (20.1) | 32 (14.5) |
1 These elements are dried then bagged before shipping, unless specified WET.
2 Internal diameter unless specified OD (outside diameter).
3 The element diameter (dimension C) is designed for optimum performance in GE
pressure vessels. Other pressure vessel dimension and tolerance may result in
excessive bypass and loss of capacity.
Table 3: Operating and CIP parameters
Typical Operating Pressure | 140 – 400psi (965-2,758kPa) |
Typical Operating Flux | 10-18 GFD (17-30 LMH) |
Maximum Operating Pressure | 450psi (3,103kPa) |
Maximum Temperature | Continuous operation: 86°F (30°C) Clean-In-Place (CIP):: 86°F (30°C) |
pH Range | Continuous operation: 5.0-6.5, Clean-In-Place (CIP): 3.0-8.0 |
Maximum Pressure Drop | Over an element: 12psi (83kPa) Per housing: 50psi (345kPa) |
Chlorine Tolerance | 1ppm maximum continuous 30ppm for 30 min during sanitization |
Feedwater2 | NTU < 1 SDI < 5 |