RO Pretreatment: Chemical to Mechanical! Complete Water Solutions was called out to a customer in Missouri regarding problems with their paint line Reverse Osmosis System. The customer was experiencing excessive membrane replacements (8 Membranes 2x A Year) and had several other mechanical problems. The customer was currently using antiscalant and bisulfite After performing an onsite Preventative Maintenance (learn more click here), we discovered that the antiscalant was being overdosed and the same with the bisulfite, after further inspection the bisulfite dosing changed daily to chlorine feed changed daily.
The Magnum Softener Selected
- S21-A Part #3023723 Magnum Softener System
- NSF 44 Certified Fiberglass Tanks
- Brine Tank w/ Cover & Air Check
- Magnum IT Valve
- Logix 764 Controller For Regeneration Sequence Control
- Interlock provided on alternating systems to maintain continuous flow during regeneration
- 120 vac 60 Hz
- 21″ x 62″ Tanks
- 24″ x 50″ Brine Tank
- 6 Cubic Feet Resin
- 2″ Connections
The Magnum Carbon Filter Selected
- C30-S Part #3023714 Magnum Carbon Filter System
- NSF 44 Certified Fiberglass Tank
- Magnum IT Valve
- Logix 764 Controller For Regeneration Sequence Control
- 120 vac 60 Hz
- 30″ x 72″ Tank
- Backwash Lock Out Control
- 15 Cubic Feet Carbon Media
- 2″ Connections
RO Pretreatment: Chemical to Mechanical from CWS
The installation of this system took place in 3 days. From Demo To Operation. If you are having problems with your RO System please don’t hesitate to contact Complete Water Solutions (855) 787-4200 or info@complete-water.com
28 Year Of Water Treatment Equipment Experience. I have been blessed with the opportunity to learn from the ground up. Starting in the water treatment field as a service technician. Servicing all major brands of water treatment equipment. Give Us A Call (855) 787-4200 or Email info@complete-water.com