Description
QuantumFluxâ„¢ P0915-IP
QuantumFlux™ UF/MBR hollow-fiber membranes are manufactured using PVDF (polyvinylidene fluoride) chemistry through the Thermally Induced Phase Separation (TIPS) process, ensuring exceptional chemical and mechanical durability.
These membranes are offered in a range of module configurations, allowing users to select the optimal setup for new projects and enabling seamless retrofit in existing installations.
All models have a hollow-fiber nominal pore size of 0.04 μm
*TIPS: Thermally Induced Phase Separation
Specifications
Specifications
| Manufacturer |
LG Chem |
| Series |
QuatumFlux |
| Model Number |
PO915-IP |
| Part Number |
PO915-IP |
| Description |
Key Features
- Excellent Mechanical Durability
- Excellent Chemical Durability
- Optimized Module Internal Design
- Outside-in Filtration
Main Benefits
- Exceptional mechanical strength reduces fiber breakage and extends fiber lifespan
- Excellent resistance to acids, caustics and oxidants
- Minimized solid accumulation and membrane fouling
- Versatile operation for a wide range of solid loadings
Port Type: Single
Filtration Surface Area: 51 m²
Module Diameter: 225 mm
Module Length: 1,500 mm
Dimension Parameters
Filtration Surface Area (m2) [ft2]: 51 [549]
Column Volume (L) [gal]: 49 [12.96]
Empty Weight (kg) [Ibs]: 53 [116]
L1 (mm) [inches]: 1,988 [78.2]
L2 (mm) [inches]: 1,864 [73.4]
L3 (mm) [inches]: 1,689 [66.5]
L4 (mm) [inches]: 1,500 [59.1]
L5 (mm) [inches]: 180 [7.1]
R (mm) [inches]: 225 [8.9]
Port Configuration
Port A (mm) [inches]: Feed/Discharge - DN100 [4] Victaulic Grooved Pipe
Port B (mm) [inches]: Concentrate - DN100 [4] Victaulic Grooved Pipe
Port C (mm) [inches]: Filtrate - DN40 [1½] Union Nut & Joint
Port D: Air Inlet - Hose Adapter: OD-12 mm, ID-9.5 mm [3/8 inches]
Operating Parameters
Typical Filtrate Flowrate (m³/hr) [gpm]: 2.0–6.1 [8.9–26.9]
Filtration Mode: Outside-in
Typical Flux (LMH) [gfd]1: 40–120 [25–70]
Operating Temperature (°C) [°F]: 5–40 [41–104]
pH Range:
Operating: 2-12;
Cleaning: 1-14
Air Scour Flowrate (m³/hr/module) [cfm]: 5-12 [2.9-7.1]
Instantaneous Chlorine Tolerance (ppm): 10,000
Maximum Lifetime Chlorine Tolerance (ppm-hrs): 3,000,000
Maximum Feed Turbidity (NTU)²: 300
Maximum Transmembrane Pressure (bar) [psi]: 2.1 [30]
Maximum Feed Pressure (bar) [psi]³: 6.25 [91]
Oil Content in Feed Water (ppm): < 2
Allowed Particle Size in Feed Water (mm)²:
≤ 0.5
≤ 0.12 for Seawater Feeds
|