FilmTec – RO Membranes – Nanofiltration <4" - NF270-4040

We ship to
Please login or register to see downloads

Description

FilmTecâ„¢ Nanofiltration 4″ Elements

FilmTecâ„¢ Nanofiltration 4″ Elements allow selective separation of organics and salts for medium-sized industrial and municipal water treatment plants that produce less than approximately 10 gpm (2300 L/h) of permeate.
FilmTec™ NF270-4040 Elements are ideal for removing a high percentage of TOC and THM precursors with medium to high salt passage and medium hardness passage in commercial systems. The NF270 nanofiltration membrane is an ideal choice for surface water and ground water where good organic removal is desired with partial softening.  FilmTec NF270-4040 elements are tape-wrapped.

Uses

Advantages

Specifications

Looking for downloads for this product? Follow the two simple steps below.

Step 1
LoginorCreate Account
Step 2

View downloads!

Downloads

Specifications

Manufacturer Filmtec
Series <4" Nanofiltration
Model Number NF270-4040
Part Number 149987
Description Typical properties for nf270-4040
Active Area ft² (m²): 82 (7.6)
Applied Pressure psi (bar): 70 (4.8)
Permeate Flow Rate gpd (m³/d): 2,500 (9.5)
Stabilized Salt Rejection: >97.0%

Dimensions in (mm)
A 40.0 (1,016)
B 3.9 (99)
C 0.75 (19)
D 1.05 (27)

Suggested Operating Conditions Old
Membrane Type: Polyamide Thin-Film Composite
Maximum Operating Temperature: 113°F (45°C)
Maximum Operating Pressure: 600 psig (41 bar)
Maximum Feed Flow Rate: 4040 elements 16 gpm / 2540 elements 6 gpm
Maximum Pressure Drop: Tape wrapped: 13 psig (0.9 bar) / Fiberglassed: 15 psig (1.0 bar)
pH Range, Continuous Operation: 2 - 11, Short-Term Cleaning (30 min) 1 - 12
Maximum Feed Silt Density Index: SDI 5
Free Chlorine Tolerance: < 0.1 ppm

Suggested Operating Conditions New
Membrane Type: Polypiperazine Thin-Film Composite
Maximum Operating Temperature: 113°F (45°C)
Maximum Operating Pressure: 600 psi (41 bar)
Maximum Pressure Drop: 15 psi (1.0 bar)
pH Range
Continuous Operation:1 3 - 10
Short-Term Cleaning: (30 min.)2 1 - 12
Maximum Feed Flow: 16 gpm (3.6 m3/h)
Maximum Feed Silt Density Index (SDI): SDI 5
Free Chlorine Tolerance: < 0.1 ppm