Typical Operating Pressure 70 psi (483 kPa gage)
Typical Operating Flux 10-20 GFD (17-34 LMH)
Maximum Operating Pressure 200 psi (1380 kPa gage)
Maximum Temperature Continuous operation: 122°F(50°C) Clean-In-Place (CIP): 122°F(50°C)
pH range Optimum rejection: 7.0-7.5, Continuous operation 2.0-11.0, Clean-In-Place (CIP): 1.0-13.0(1)
Maximum Pressure Drop Over an element: 12 psi (83 kPa) Per housing: 50 psi (345 kPa)
Chlorine Tolerance 1,000+ ppm-hours, dechlorination recommended
Feedwater NTU <1 SDI 15 < 5