The AG LE H Series of thin-film reverse osmosis (RO) elements are designed to perform in brackish water applications where the customer and application seek to balance low energy and high rejection requirements. AG LE H Series elements optimize Veolia chemistry and manufacturing advancements to deliver differentiated performance over the life of the element. In contrast to ultra-low energy AK H Series, the AG LE H Series elements are often used with the need to control flux due to increased risk of fouling such as when a surface water source is used.
All AG LE H Series elements have NSF/ANSI/CAN 61 certification and halal certification.
Typical Operating Pressure: 150 psi (1,034 kPa)
Typical Operating Flux: 10-20 GFD (15-35 LMH)
Maximum Operating Pressure: 600 psi (4,137 kPa)
Maximum Temperature:
Continuous operation: 122°F(50°C)
Clean-In-Place (CIP): 122°F (50°C)
pH Range:
Optimum rejection: 7.0-7.5
Continuous operation 2.0-11.0
Clean-In-Place (CIP): 1.0-12.0 (4)
Maximum Pressure Drop:
Over an element: 15 psi (103 kPa)
Per housing: 50 psi (345 kPa)
Chlorine Tolerance: 1,000+ ppm-hours, dechlorination recommended
Feedwater: NTU < 1 SDI15 < 5